What was found
C-CHECK NON ROUTINE N0413, FRAME SUPPORT FROM 69 TO 70 STRINGER 23R BELOW SHEAR PLATE HAS 2 AREAS OF CORROSION TOTALING 2 SQUARE INCHES. REMOVED AND REPLACED FRAMES SUPPORT IAW A319 SRM 51-42-11 PARA 6 AND 7.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
C-CHECK NON ROUTINE N0413, FRAME SUPPORT FROM 69 TO 70 STRINGER 23R BELOW SHEAR PLATE HAS 2 AREAS OF CORROSION TOTALING 2 SQUARE INCHES. REMOVED AND REPLACED FRAMES SUPPORT IAW A319 SRM 51-42-11 PARA 6 AND 7.