As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING HEAVY CHECK, PERFORMED EMERGENCY LIGHT OPS CHECK ON PTP PANEL. TEST FAILED WITH MESSAGE "EPSU BATTERY EMER L". LOCATED OVERWING EPSU ON LT SIDE AND PERFORMED TEST ON INDIVIDUAL UNIT. TEST FAILED WITH "BATT FAULT" LIGHT ILLUMINATED. R & R EPSU BATTERY PACK. PERFORMED OPS CHECK. EMERGENCY LIGHTS TEST "OK". ALL INDICATIONS NORMAL.