What was found
DURING CIDS RESET, SMELLED SMOKE IN COCKPIT, AFTER RESET CIDS CLEARED. PERFORMED OPS TEST OF THE CARGO SMOKE DETECTION REF 26-16-00-710-001 BITE TEST OK. PERFORMED OPS TEST OF THE LAV SMOKE DETECTION SYS, REF 26-17-00-710-001. OPS TEST OK. PERFOMED BITE OF CIDS IAW AMM 23-73-00-740-005A. OPS TEST OK, NO SMOKE SEEN/FOUND. OK FOR SERVICE.