What was found
GREEN SERVICE, ENG 1 OVERHEAT, TROUBLE SHOT GREEN HYD SYS IAW TSM 29-11-00-810-800-A. REPLACED PTU IAW AMM 29-23-41 PB401. LEAK AND OPS CHECKED NORMAL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
GREEN SERVICE, ENG 1 OVERHEAT, TROUBLE SHOT GREEN HYD SYS IAW TSM 29-11-00-810-800-A. REPLACED PTU IAW AMM 29-23-41 PB401. LEAK AND OPS CHECKED NORMAL.