VENT VANES SVS FAULT IN FLIGHT. GENERATOR 1 LINE SMOKE INDICATION UPON LANDING NO VISIBLE SMOKE SEEN OR SMELLED IN FLIGHT DECK OR IN CABIN. NO EVIDENCE FOUND OF SMOKE PERFORMED SYS RESET NO FAULT NOTED REF AMM AMM 21-26-00 PB 501.