As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AIRCRAFT OUT OF SERVICE FOR C7-S2 CHECK. AFT CABIN FLOORBEAM JUST IN FRONT OF R2 DOOR HAD MINOR CORROSION AT FR 68, -Y1292. REMOVED CORROSION. CHECKED LIMITS. FOUND OUT OF LIMITS REF SRM 53-00-14 PB10L. 4.B. FIGL02. R & R FLOORBEAM REF SRM 51-42-11. PAR 5, A-C.