What was found
ACFT OUT OF SERVICE FOR C7-S2 CHECK. MAIN CABIN FLOORBEAM HAS CORROSION ONE FWD OF FR68 Y765. REMOVED CORROSION, FOUND OUT OF LIMITS IAW SRM 53-00-14, PB10L, 4.B, FIG L02. R & R FLOORBEAM IAW SRM 51-42-11, PAR5, A-C.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ACFT OUT OF SERVICE FOR C7-S2 CHECK. MAIN CABIN FLOORBEAM HAS CORROSION ONE FWD OF FR68 Y765. REMOVED CORROSION, FOUND OUT OF LIMITS IAW SRM 53-00-14, PB10L, 4.B, FIG L02. R & R FLOORBEAM IAW SRM 51-42-11, PAR5, A-C.