Service difficulty report · Check Valve · Airbus A319112

Difficulty date
April 2, 2015
Submitted
April 6, 2015
Operation
Air carrier
Aircraft
N954FR
Make and model
Airbus A319112
Aircraft serial
1786
Aircraft time
33,018 hours, 22,924 cycles
Part
Check Valve
Part number
769B000001
Part serial
0769B00L1003928
Condition
Damaged
Location
Ac Bay
Part time
33,018 hours, 22,924 cycles
Stage of operation
CL
How discovered
O
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

DISCREPANCY, UNABLE TO MAINTAIN CABIN PRESS AT FL 320. CABIN ALT WAS 10,150 & CLIMBING. FOUND NR 1 PACK FUSELAGE CHECK VLV MISSING & ABOUT 3 SQUARE INCHES OF ITS FLAPPER & BELLOWS BLOWN OUT. REPLACED BELLOWS & FUSELAGE CHECK VLV. PRESSURIZED ACFT WITH NO FAULTS FOUND. SEE NR 112107 & LP 900227.