What was found
DURING C CHECK INSPECTION NOTED AFT WET AREA FLOOR STRUCTURE AFT RT CORNER, BETWEEN FRAME 69 & 70, SHEAR PLATE CORRODED. R & R AFT WET AREA FLOOR STRUCTURE LT CORNER, FRAME 69 & 70, SHEAR PLATE IAW SRM 51-42-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C CHECK INSPECTION NOTED AFT WET AREA FLOOR STRUCTURE AFT RT CORNER, BETWEEN FRAME 69 & 70, SHEAR PLATE CORRODED. R & R AFT WET AREA FLOOR STRUCTURE LT CORNER, FRAME 69 & 70, SHEAR PLATE IAW SRM 51-42-11.