What was found
CORROSION ON FLOORBEAM Y1292, FASTENER HOLE BETWEEN FRAME 20 AND FRAME 18. R & R FLOORBEAM AT Y1292, FRAME 12-24 IAW SRM 51-72-11-911 AND SRM 51-21-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON FLOORBEAM Y1292, FASTENER HOLE BETWEEN FRAME 20 AND FRAME 18. R & R FLOORBEAM AT Y1292, FRAME 12-24 IAW SRM 51-72-11-911 AND SRM 51-21-11.