What was found
LAVATORY WASTE VACUUM PORT SKIN CRACKING. CUTOUT DAMAGE, FABRICATED AND INSTALLED DOUBLER, FILLERS AND CONNECTION PLATE. RESTORED AREA IAW SRM 53-41-11-300-004 FIG 2, AMM 25-55-12-000-001-A, AND 25-55-12-420-050 B.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LAVATORY WASTE VACUUM PORT SKIN CRACKING. CUTOUT DAMAGE, FABRICATED AND INSTALLED DOUBLER, FILLERS AND CONNECTION PLATE. RESTORED AREA IAW SRM 53-41-11-300-004 FIG 2, AMM 25-55-12-000-001-A, AND 25-55-12-420-050 B.