What was found
DISCREPANCY: REFERENCE LOG PAGE LP1112557 ITEM 1, RMP 1 MALFUNCTION VERY STRONG ELECTRICAL ODOR. CORRECTIVE ACTION: REMOVED AND REPLACED 1RG1 RMP REF AMM 23-13-13-400-001-A. OPS TEST OK, A/C OK TO CONTINUE./END/
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DISCREPANCY: REFERENCE LOG PAGE LP1112557 ITEM 1, RMP 1 MALFUNCTION VERY STRONG ELECTRICAL ODOR. CORRECTIVE ACTION: REMOVED AND REPLACED 1RG1 RMP REF AMM 23-13-13-400-001-A. OPS TEST OK, A/C OK TO CONTINUE./END/