What was found
AFT CABIN, FLOORBEAM Y254, FR69+ 18.5, TOP FLANGE UPR SURFACE, CENTER FASTENER HOLE CORRODED. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS IAW SRM 53-00-14-283-002. REMOVED & REPLACED FLOORBEAM IAW SRM 51-72-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT CABIN, FLOORBEAM Y254, FR69+ 18.5, TOP FLANGE UPR SURFACE, CENTER FASTENER HOLE CORRODED. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS IAW SRM 53-00-14-283-002. REMOVED & REPLACED FLOORBEAM IAW SRM 51-72-11.