What was found
DISCREPANCY: REFERENCE LP 210431 ENG 1 STALL CAUTION MSG. ENGINE PARAMETERS NORMAL AFTER CAUTION WENT AWAY. CORRECTIVE ACTION: PERFORMED TSM 77-11-00-810-815-A, THERE WAS NO AUDION EVIDENCE REPORTED AND NO EXCEEDANCE ON EXCEEDANCE REPORT. PERFORMED INSPECTIONS ODF STEP 4.A1(1)(B) NO DISCREPANCIES NOTED. PER THE SAM STEP, NO FURTHER ACTION IS NECESSARY, AC OK FOR SERVICE TSM 77-11-00-810-815-A