As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DISCREPANCY: REFERENCE AIRBORNE/PEMCO N/R 13872.0389 AIRCRAFT WAS NOT GROUNDED AND IS IN CHECK FOR SCHEDULED MX. DURING PRIMARY INSPECTION WAS FOUND SERVAL CORROSION ON AFT WET AREA- R/H LATERAL SHEAR PLARE BETWEEN FR68 TO FR70 CORRECTIVE ACTION: REMOVED AND REPLACED MAIN CABIN AFT WET AREA FR69-70 R/H SHEAR PLATE IAW A320 SRM 51-72-11. OPS CHECK OF VACUM GENERATOR TRANSFERED TO PEMCO LEAK AND FUNCTIONAL CHECK WORK SHEET 13871.0756 PG9 ITEM #35. MX ACTION IS ACCEPTABLE./END/