What was found
PAE - FOUND CRACK IN FRAME WEB AT UPPER CORNER OF STRINGER CUTOUT BS 294.5, STRINGER 18R. FOUND CRACK CONTAINED IN FASTENER HOLE. REPAIRED PER SRM 51-40-02 AND TRAMCO ER100396MW3. WORK DOCUMENTED ON TRAMCO MWO FUSELAGE 233. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PAE - FOUND CRACK IN FRAME WEB AT UPPER CORNER OF STRINGER CUTOUT BS 294.5, STRINGER 18R. FOUND CRACK CONTAINED IN FASTENER HOLE. REPAIRED PER SRM 51-40-02 AND TRAMCO ER100396MW3. WORK DOCUMENTED ON TRAMCO MWO FUSELAGE 233. (M)