What was found
PAE - FOUND CORROSION (C53-107-02) ON FLOORBEAM BS 328, RBL 10 TO RBL 41, WL 208. REMOVED CORROSION IN AN AREA OF 3 INCH BY 18 INCH WITH A DEPTH OF .028 INCH AND AN ORIGINAL THICKNESS OF .080 INCH, FOUND TO BE OUT OF LIMITS PER SRM 53-10-01. REMOVED AND REPLACED UPPER T-CHORD. ALL WORK DONE IAW SRM 53-10-01, 53-10-02, AND 53-10-9. (M)