As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
PAE - FOUND CORROSION (C53-107-02) ON FLOORBEAM BS 344, RBL 10, WL 208. REMOVED .028 INCH OF MATERIAL 4 INCHES BY 2 INCHES FROM ORIGINAL THICKNESS OF .080 INCH. FOUND TO BE OUT OF LIMITS IAW SRM 53-10-01. FABRICATED AND REPLACED IAW SRM 53-10-09 INSTALLED PARTS IAW SRM 51-40-03 ON FLOOR BEAM, BS 344 RBL 10, WL 208. (M)