PAE - AT STATION 500B PLUS 2.5, STRINGER 16L IS CRACKED, LENGTH OF CRACK .25 INCH. CUTOUT DAMAGED AREA AND REPAIRED PER TRAMCO EWO NR 97-0115 AND BOEING SB 737-53-1145. WORK ACCOMPLISHED ON TRAMCO WORK ORDER NR INTERIOR 262. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PAE - AT STATION 500B PLUS 2.5, STRINGER 16L IS CRACKED, LENGTH OF CRACK .25 INCH. CUTOUT DAMAGED AREA AND REPAIRED PER TRAMCO EWO NR 97-0115 AND BOEING SB 737-53-1145. WORK ACCOMPLISHED ON TRAMCO WORK ORDER NR INTERIOR 262. (M)