What was found
PAE - A .5 INCH CRACK IN THE UPPER FORWARD CORNER OF THE FORWARD ENTRY DOOR CUTOUT SKIN. WHILE ACCOMPLISHING EA 53-737-023 INADVERTENTLY OVERSIZED 34 HOLES ABOVE ALLOWABLE LIMITS IN BOEING SB 737-53-1163. REPAIRED DAMAGED HOLES IAW TRAMCO EWO 97-0140 BY OVERSIZING AND INSTALLING FREEZE PLUGS, REPLACING, DAMAGED SUB-STRUCTURE AND DOOR STOP FITTINGS, AND INSTALLING A THICKER AND LARGER REPAIR DOUBLER. WORK ACCOMPLISHED IAW TRAMCO EWO 97-0140, BOEING DRAWING 65C36941-5, SRM 51-10-01, 51-10-2, 51-30-2. REF WORK ORDERS 214932 DOORS 51, INTERIOR 264. (M)