What was found
PAE - FOUND CORROSION (C53-202-01) ON FRAME BS 300B BETWEEN STRINGER 24 AND 25 LEFT. REMOVED CORROSION AT BS 500B BETWEEN STRINGER 24 AND 25 LEFT, 2 INCHES LONG BY 1 INCH WIDE, ORIGINAL THICKNESS .050. REMOVED 20 PERCENT, FOUND TO BE OUT OF LIMITS. REMOVED DAMAGED AREA. FABRICATED REPAIR DOUBLER AND INSTALLED IAW SRM 51-40-3, 53-10-1, 53-10-1. (M)