What was found
PAE - DURING C-CHECK INSPECTION, REPORTED CORROSION IN LUG BOLT HOLES FOR AFT STABILIZER FITTING ON LEFT MIAN LANDING GEAR SUPPORT BEAM. MAINTENANCE REMOVED CORROSION PER ER 98-0370, FABRICATED REPLACEMENT PARTS AND REPAIRED PER ER 98-0370 AND SRM 51-10-0. (M)