What was found
PAE - DURING C-CHECK, INSPECTION REPORTED CORROSION AND CRACK ON SHEAR TIE AT BS 727A, WL 149, RBL 13. MAINTENANCE FABRICATED REPLACEMENT SHEARTIE AND REPAIRED PER SRM 53-10-1, 51-30-2 AND 53-10-4. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PAE - DURING C-CHECK, INSPECTION REPORTED CORROSION AND CRACK ON SHEAR TIE AT BS 727A, WL 149, RBL 13. MAINTENANCE FABRICATED REPLACEMENT SHEARTIE AND REPAIRED PER SRM 53-10-1, 51-30-2 AND 53-10-4. (M)