What was found
PAE - DURING C-CHECK, INSPECTION REPORTED CORROSION ON SHEAR TIE AT BS 1006, LBL 4 THROUGH RBL 4, WL 178. MAINTENANCE REMOVED CORRODED AREA, 1.5 INCH BY 2.5 INCH. FABRICATED REPLACEMENT PARTS AND REPAIRED PER SRM 51-10-2 AND 51-30-2. (M)