PHX - FLT 429 - DURING DESCENT INTO PHX, FLIGHT CREW REPORTED NR 1 GENERATOR OFF BUS LIGHT ILLUMINATED FOLLOWED BY THE SMELL OF ELECTRICAL SMOKE WITH A SMALL AMOUNT OF VISIBLE SMOKE NOTICED. COMPLIED WITH SMOKE REMOVAL CHECKLIST AND SMOKE DISSIPATED. AIRCRAFT LANDED WITHOUT INCIDENT. MAINTENANCE REPLACED GENERATOR CONTROL UNIT AND CHECKED OK. (M)