What was found
PAE - DURING C-CHECK INSPECTION, REPORTED CORROSION ON CARGO FLOOR SUPPORT AT BS 772 AND BS 727E PLUS 3 INCH, LBL 2.5. MAINTENANCE REMOVED CORROSION ON FLOOR SUPPORT AT BS 727E PLUS 3 INCH, LBL 2.5 (1 INCH BY 3 INCH BY .018 INCH) AND BS 772, LBL 2.5 (1 INCH BY 3 INCH BY .015 INCH). FABRICATED REPLACEMENT PARTS AND REPAIRED PER SRM 51-40-2, 53-00-53 AND 53-60-53. (M)