What was found
PAE - DURING C-CHECK INSPECTION, REPORTED CORROSION ON SHEAR TIE AND FRAME AT BS 807, LBL 2 - RBL 3, STRINGER 27L AND 27R. MAINTENANCE REMOVED CORRODED AREA (2 INCH BY 3 INCH), FABRICATED REPLACEMENT PARTS AND REPAIRED PER SRM 51-20-01, 51-30-2, 53-00-07 AND 53-60-07. (M)