What was found
PAE - DURING C-CHECK INSPECTION, REPORTED CORROSION ON STRAP UNDER FRAME AT BS 794.5, RBL 23, WL 156. MAINTENANCE REMOVED CORROSION (1 INCH BY 8 INCH BY .025 INCH), AND REPAIRED PER SRM 51-40-02 AND 53-00-07. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PAE - DURING C-CHECK INSPECTION, REPORTED CORROSION ON STRAP UNDER FRAME AT BS 794.5, RBL 23, WL 156. MAINTENANCE REMOVED CORROSION (1 INCH BY 8 INCH BY .025 INCH), AND REPAIRED PER SRM 51-40-02 AND 53-00-07. (M)