What was found
PAE - DURING C-CHECK, INSPECTION REPORTED CORROSION ON RT HORIZONTAL STABILIZER REAR LOWER CLEVIS ON FORWARD SIDE AROUND BUSHING. MAINTENANCE BLENDED CORROSION (1 INCH BY .035 INCH BY .081 INCH; .15 INCH BY .4 INCH BY .023 INCH; .15 INCH BY .7 INCH BY .037 INCH; .3 INCH BY .5 INCH BY .046 INCH; .13 INCH BY .40 INCH BY .049 INCH; .15 INCH BY .40 INCH BY .062 INCH; AND, .10 INCH BY .50 INCH BY .065 INCH). INSTALLED NEW BUSHING AND REPAIRED PER SRM'S 51-10-8, 55-10-1, OHM 20-10-3, AND ER 98-0704. CYCLES: 1,941. (X)