What was found
PAE - DURING C-CHECK, INSPECTION REPORTED CRACK IN NR 2 SLAT CENTER UPSTOP CUT-OUT FIXED LEADING EDGE. MAINTENANCE REMOVED DAMAGED AREA, FABRICATED REPLACEMENT PARTS AND REPAIRED PER SRM 51-10-1 AND ER 98-06-89. CYCLES: 1,941. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PAE - DURING C-CHECK, INSPECTION REPORTED CRACK IN NR 2 SLAT CENTER UPSTOP CUT-OUT FIXED LEADING EDGE. MAINTENANCE REMOVED DAMAGED AREA, FABRICATED REPLACEMENT PARTS AND REPAIRED PER SRM 51-10-1 AND ER 98-06-89. CYCLES: 1,941. (X)