What was found
DEN - DURING C-7 CHECK, INSPECTION REPORTED CORROSION ON INTERCOSTAL BETWEEN FLOORBEAMS 277 AD 294. MAINTENANCE FABRICATED REPLACEMENT PARTS AND REPAIRED PER SRM 53-10-2, FIG 7, AND EA 53-737-047. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DEN - DURING C-7 CHECK, INSPECTION REPORTED CORROSION ON INTERCOSTAL BETWEEN FLOORBEAMS 277 AD 294. MAINTENANCE FABRICATED REPLACEMENT PARTS AND REPAIRED PER SRM 53-10-2, FIG 7, AND EA 53-737-047. (M)