What was found
STRUT NR 2 INBD SIDE OF SKIN AT APPROX PPS 200.50 HAS EXFLOIATED CORROSION (APPEARS TO BE TRAVELING UNDER FRAME/CORD ALSO). REMOVED SKIN IAW SRM 51-40-02. REMOVED CORROSION AT STA 157, ORIGINAL MATERIAL THICKNESS .090", REMAINING THICKNESS .062", OUT OF LIMITS IAW SRM 54-50-01. REMOVED AND RE-INSTALLED INBD SUPPORT FITTING AND PLATE, 3EA ACCESS DOORS, 2EA BULB SEALS, HEAT SHIELD, AND INBD FAIRING IAW ARM 51-40-02 TO FACILITATE SKIN REMOVAL & INSTALLATION, INSTALLED REPAIR SKIN IAW DWG 311N5002 AND SRM 51-40-02. THIS IS A MAJOR REPAIR CATAGORY A NO FOLLOW UP TRACKING REQUIRED.