What was found
AT CRUISE FLT, NR 2 HYDRAULIC QTY AND PRESSURE WENT TO ZER0. NO HIGH TEMP INDICATED. COMPLIED WITH QRH AND RETURNED TO MEMPHIS. REMOVED AND REPLACED 2/1 NON-REV MOTOR PUMP SHUTOFF VALVE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AT CRUISE FLT, NR 2 HYDRAULIC QTY AND PRESSURE WENT TO ZER0. NO HIGH TEMP INDICATED. COMPLIED WITH QRH AND RETURNED TO MEMPHIS. REMOVED AND REPLACED 2/1 NON-REV MOTOR PUMP SHUTOFF VALVE.