What was found
AFTER REMOVAL DOUBLER FROM TV MONITOR SUPPORT AT STA 1320. FOUNDED SEVERAL HOLES ON FRAME. REMOVED DAMAGE AT STA 1320 FROM STR 4L-4R IAW SRM 53-00-07. FABBED ZEE FRAME FROM MAE TRAVELER T8/763299. FABBED SPLICES IAW MAE TRAVELER T8/761975. DRILLED REPAIR PARTS IAW SRM 53-00-07. TREATED AND PRIMED REPAIR PARTS IAW SRM 53-00-07 REPAIR 3. INSTALLED REPAIR PARTS IAW SRM 53-00-07, FIG 201 REPAIR NR 3 AT STA.1320. DO A HFEC INSPECTION EVERY 12,000 FLIGHT CYCLES AS GIVED IN NDT PART 6,51-00-01. REPEAT THIS INSP AT EVERY 12,000 FIGHT CYCLES INTERVALS, AS AN ALTERNATIVE, DO A (DVI) INSP AT 9,000 FLIGHT CYCLES INTERVALS AFTER INITIAL INSP IAW NOTES D53-00-07. THIS IS A CT "B' REPAIR. " MAJOR REPAIR"