What was found
MAIN DECK BULKHEAD SUPPORT CORRODED AT AFT BULKHEAD FITTING STA 1183 LBL 18, WL 208. REMOVED CORROSION, OUT OF LIMITS .018 MATERIAL REMOVED, ORIGINAL MATERIAL .063, .045 REMAINING. INSTALLED DOUBLER AND SPLICED FLOOR SUPPORT REF SRM 51-40-3 PG 1, DWR 65-31774. THIS IS CLASSIFIED AS A MAJOR REPAIR. TREATED AND PRIMED REPAIR SPLICE AND DOUBLER REF SRM 51-10-2.