What was found
MLG FAILED TO RETRACT, TRIED BOTH SYS 1 2. RTF. FOLLOWED TSM 32-30-00, CHECKED PROX DET, RT BOGIE FAIL. INSP RT MLG BOGIE BEAM SENSOR 12GA. REMOVING DETECTOR SUPPORT BOLT, FOUND WATER IN HOUSING. REMOVED, DRIED & LUBED IAW MM 32-11-14-6. INSP PITCH DAMPER IAW MM 12-12-32-0. TESTED PROX DETECT UNIT, FAULT CLEARED. RESET/TESTED AGAIN, NO FAULTS RECORDED. IAW MM 32-31-71-4. R&R PROX DETECT UNIT PER MM 32-31-71-4. PERFORMED OPS CHECK. OK. LUBED PIVOT PIN IAW MM 112-22-32-0. SWUNG MLG SEVERAL TIMES. ALL 3 MLG RETRACT & EXTEND NORMAL IN 1&2. DISCONNECTED PITCH DAMPERS ON MAINS, CHECKED MOVEMENT OF BOGIES. NO BINDING IAW MM 32-11-15-4. RECONNECTED PITCH DAMPERS & CHARGED SYS IAW MM 12-12-32-0. OK FOR SERVICE.