What was found
FALSE SPAR CHORD CRACKED UNDER NR 8 SPOILER . TRIMMED INBRD WEB SECTION IAW DRAWING SR 27-57-038 REV C. TRIMMED LOWER STRUCTURE IAW DRAWING SR 27-57-038. LOCATED, DRILLED, DEBURRED LOWER ANGLE IAW 51-30-5 & DWG SR 27-57-038 REV C. FABRICATED 2 EA ANGLES AND FABRICATED STRAP IAW DWG SR 27-57-038 AND SRM 51-30-5. FABRICATED DOULBLER AND HEAT TREATED ANGLES AND DOUBLER TO 7075-T6 AND 7075-T4 IAW WITH ENG REPORT 2-37153-801 REV A. TREATED AND PRIMED REPAIR PARTS IAW SRM 51-10-2 AND INSTALLED REPAIR PARTS IAW FX DWG SR27-57-038.