What was found
AFT CARGO PIT STA 1560 STR 24-25R, FRAME AND FRAME SPLICE ARE GOUGED. BLENDED AND SMOOTHED FRAME FOUND WITHIN LIMITS IAW SRM 53-60-07 AND SRM 53-00-07 FIG 101 DETAIL 2. REMOVED AND FABRICATED NEW SPLICE FRAME WITH MAE TRAVELER NR T8/771003, LOCATED, DRILLED HOLES, TREATED, PRIMED, PAINTED AND INSTALLED SPLICE FRAME IAW SRM 51-40-02. THIS IS MAJOR AND CATEGORY "A" REPAIR.