What was found
PREVIOUS REPAIR AT BS 312 STR 24R HAS IMPROPERLY INSTALLED FASTENERS, AND FOUND GOUGES, AND TOOLING MARKS. REMOVED PREVIOUS REPAIR AT BS 312 STR 24R IAW SRM 51-30-2. CUT OUT DAMAGED AREA IAW SRM 51-10-1. CUT OUT DIMENSIONS 3.8" X 4.1". FABRICATED REPAIR FILLER. FABRICATED FILLER AND FABRICATED DOUBLE IAW SRM 53-30-2 FIG 2, 53-30-3 FIG 5, 51-30-5, AND 51-30-8. TREATED AND PRIMED REPAIR PARTS IAW SRM 51-10-2 AND INSTALLED REPAIR PARTS IAW SRM 51-30-2.