What was found
AFT PIT FWD BULKHEAD AT S43L, CORROSION ON END FITTING. REMOVED CORROSION, FOUND TO BE OUT OF LIMITS IAW SRM 53-15-14; FIG 7; SHEET 2. REMOVED FITTING IAW SRM 51-40-21. RECEIVED NEW FITTING, LOCATED & DRILLED NEW FITTING IAW DWG A53811093. INSTALLED FITTING IAW SRM 51-40-21.