What was found
AFT AIRSTAIRS, LT TORQUE BOX I/B VERTICAL WEB IS CRACKED AT BS.1225, WB 190 APROX REMOVED AFT AIRSTAIRS FLOOR PANEL AND ANGLE FOR ACCESS IAW SRM 51-30-2. CUTOUT DAMAGED AREA IAW SRM 51-40-2 FIG 1. FABRICATED REPAIR PART AND FILLER IAW SRM 53-10-2 FIG 6 AND 51-40-2 FIG 1. TREATED AND PRIMED PARTS IAW SRM 51-10-2. INSTALLED REPAIR PART AND FILLER IAW SRM 51-30-2. INSTALLED AFT AIRSTAIRS AND ANGLE IAW SRM 51-30-2.