What was found
GOUGED FRAME ON STA 580, STR 3L REMOVED FASTENERS IAW SRM 51-30-2, BLENDED OUT DAMAGE AREA IAW SRM 51-10-1. UT AREA IAW NDTM 51-00-00 FIG 2 PT 4. HFEC AREA IAW NDTM 51-00-00 FIG 23 PT 6. NO DEFECTS NOTED. FOUND TO BE OUT OF LIMITS IAW FDX SRM 53-10-1 FIG 1A. FABRICATED REPAIR ANGLE AND HEAT TREATED TO 7075 T6 IAW FAS REPORT NR2 -37153-801 REV A AND EA NR 7-5310-12688. LOCATED, DRILLED, AND DEBURRED REPAIR ANGLE IAW SRM 51-30-5 AND EA NR 7-5310-12688. TREATED AND PRIMED REPAIR PARTS IAW SRM 51-10-2 AND EA NR 7-5310-12688 AND INSTALLED REPAIR PARTS IAW SRM 51-30-2 AND EA NR 7-5310-12688.