As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FWD PIT BILGE FRAME NR 37 BETWEEN STRINGER 51L AND STRINGER 52L SHEAR TIE HAS CORROSION ON THE AFT SURFACE. REMOVED SHEAR TIE FROM FRAME 37 IAW SRM 51-40-21. REMOVED CORROSION IAW SRM 51-73-10. ORIGINAL MATERIAL 0.055 IAW SRM 53-14-13. REMAINING MATERIAL 0.042 IAW DWG 6-17-09. FOUND TO BE OUT OF LIMITS IAW SRM 53-73-10. LOCATED AND DRILLED NEW SHEAR TIE IAW SRM 51-40-40. ALODINED IAW SRM 51-21-00. PRIMED IAW SRM 51-24-00. INSTALLED IAW SRM 51-40-21.