What was found
CRACK INDICATION FOUND DURING HIGH FREQUENCY EDDY CURRENT OPEN HOLE INSP ON 0.460 INCH HOLES AT MAIN CARGO DOOR LWR JAMB, NR 4 SUPPORT FITTING AT HOLES A, B, C AND D. BUSHING REPAIR CARRIED OUT AS PER SRM 53-50-00 FIGURE 10 VOLUME I. REPAIR CLASSIFIED AS MAJOR AS PER GMM 6-2-100.