What was found
DENT STA 1180 STR 17R. FOUND DENT OUT OF LIMITS, CUT OUT DAMAGED SKIN DIMS 3.2 INCH X 3.0 INCH, FABRICATED REPAIR DOUBLER USING 2024-T3 .090 DIMS 10.5 INCH X 8.750 INCH AND FILLER USING 2024-T3 .080 DIMS 3.2 INCH X 3.0 INCH, INSTALLED REPAIR DOUBLER AND FILLER IAW SRM 53-30-3 FIG 3A.