What was found
LEFT UPPER FUSELAGE AT FR 84 FROM STR 6 TO STRI 7; CHECK FOR CORROSION UNDER PAINT; THERE IS TRASH AND DEBRIS IN THE PAINT. REMOVED FASTENERS TO FOM IAW A310-200 SRM 51-40-21; PG 7. REMOVED CORROSION IAW SRM 51-24-10 AND WAS FOUND TO BE OUT OF LIMITS PER SRM 53-19-12. ACCOMPLISHED HFEC INSP OF REWORKED AREA PER NTM 51-10-01 AND FOUND 1 HOLE CRACKED. OVERSIZED HOLE TO 0.250 IAW SRM 51-40-21, PG 7. ACCOMPLISHED HFEC INSP OF THE HOLE PER NTM 51-10-08 AND NO CRACKS FOUND. PERFORMED FLAP PEEN PER EA 6-5330-123699 IAW SRM 51-29-02. I=0.15 WEAR. ALODINED IAW SRM 51-21-10. PRIMED AND PAINTED IAW SRM 51-75-10. INSTALLED FASTENERS IAW SRM 51-40-21; PG 7.