What was found
INTERCOSTAL ON L-1 DOOR THRESHOLD AREA HAS CORROSION, APPROX BS 346-361. REMOVED CHANNEL ON L-1 DOOR THRESHOLD FROM STA 346-STA 361 LT SIDE IAW SRM 51-40-02. REMOVED CORROSION IAW SRM 53-10-15. ORIG MAT 0.050 INCH REMAINING MAT 0.041 INCH FOUND TO BE OUT OF LIMIT. RECEIVED NEW CHANNEL ON MAE TRAVELER T8/774315. INSTALLED NEW CHANNEL ON STA 346-361 LBL 60 IAW SRM 51-70-12 AND SRM 51-40-02. THIS IS A CATEGORY "A" MAJOR REPAIR.