What was found
6 HOLES AT AFT END OF TEE FITTING AT FR 15 ARE ELONGATED. REMOVED DAMAGED TEE FITTING AND INSTALLED FLOOR STRUCTURE TEE SPLICING REPAIR AT FR 15 AND SEAT TRACK NR 3RT IAW SRM 53-12-15, FIG 207.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
6 HOLES AT AFT END OF TEE FITTING AT FR 15 ARE ELONGATED. REMOVED DAMAGED TEE FITTING AND INSTALLED FLOOR STRUCTURE TEE SPLICING REPAIR AT FR 15 AND SEAT TRACK NR 3RT IAW SRM 53-12-15, FIG 207.