What was found
CRACK ON LEFT INBD MID FLAP CHORD AT WBL 114. CUT OUT DAMAGED AREA IAW SRM 51-40-3 FIG 1. FABRICATED LOWER SECTION USING EXTRUSION AND SPLICE IAW SRM 51-40-3 FIG 1 AND 57-50-2 FIG 5. INSTALLED REPAIR PARTS IAW SRM 51-30-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACK ON LEFT INBD MID FLAP CHORD AT WBL 114. CUT OUT DAMAGED AREA IAW SRM 51-40-3 FIG 1. FABRICATED LOWER SECTION USING EXTRUSION AND SPLICE IAW SRM 51-40-3 FIG 1 AND 57-50-2 FIG 5. INSTALLED REPAIR PARTS IAW SRM 51-30-2.