What was found
MAIN DECK, FRAME AT RIGHT STA 1681 LONGERON 12 FOUND DENTED. REPAIRED AS PER SRM 53-30-00 FIGURE 1 VOLUME I. REPETITIVE INSPECTION REQUIRED, INITIAL INSPECTION AT 14,500 CYCLES AND REPETITIVE INSPECTION AT 9,500 CYCLES AS PER SRM 53-30-00 FIGURE 1 VOLUME I. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.